# 462100473671
Unscheduled inspection
Start date: 2021-08-17, end date: —, duration: 10
Authority: Glavnoe upravlenie MCHS Rossii po Kurskoi oblasti
Purpose of inspection: control of the execution of regulations No. 14/1/1 dated 30.03.21 and No. 4/1/1 dated 28.01.2021
# 462100063861
Unscheduled inspection
Start date: 2021-03-15, end date: 2021-04-02, duration: —
Authority: Glavnoe upravlenie MCHS Rossii po Kurskoi oblasti
Purpose of inspection: control of the execution of Regulation No. 31/1/1 dated 03.11.2020 on the elimination of violations of fire safety requirements, the deadline for which has expired
# 362100051798
Unscheduled inspection
Start date: 2021-03-22, end date: 2021-03-26, duration: 5
Authority: Verhne-Donskoe upravlenie Federalnoi sluzhby po ekologicheskomu, tehnologicheskomu i atomnomu nadzoru
Purpose of inspection: verification of Aerostar MSK LLC's compliance with the regulations of the Verkhne-Donskoy Administration of Rostechnadzor dated 11/19/2020 № P-K4/504-2425, which expired on 02/27/2021.
# 462005229520
Unscheduled inspection
Start date: 2020-11-12, end date: —, duration: —
Authority: —
Purpose of inspection:
# 462005205113
Unscheduled inspection
Start date: 2020-10-28, end date: 2020-11-03, duration: 0
Authority: Glavnoe upravlenie MCHS Rossii po Kurskoi oblasti
Purpose of inspection: Verification of the facts set out in the reasoned submission of the senior inspector of the OND and PR for gZheleznogorsk and Zheleznogorsk district, the State Inspector of gZheleznogorsk and Zheleznogorsk district of the Kursk region, Lotsmanov EA 173 dated 21102020 on the issue of violation of fire safety requirements in Aerostar MSC LLC, namely, there are no fire hydrants st99 of the Federal Law Technical Regulations on Fire Safety Requirements dated 22072008 123FZ p41 SP 8131302009 Fire protection systems are completely devoid of ventilation combustion products from welding and the paint drying furnace are distributed to neighboring rooms there is no smoke ventilation st56 of the Federal Law Technical Regulations on fire Safety requirements from 22072008 123FZ p72 pp e SP7131302013 Heating ventilation and air conditioning Fire safety requirements at night exits from the premises are padlocked sealed there is one gorenje exit the rules for storing gas cylinders are violated, namely, after the change, gas cylinders with combustible gases remain in the workplace p423 Rules of fire protection in the Russian Federation Decree of the Government of the Russian Federation of 250-42012 390 On fire protection the aisles are filled with various materials, which worsens evacuation p36 paragraph b Rules of fire protection in the Russian Federation Decree of the Government of the Russian Federation of 250-42012 390 About the fire safety regime
# 462005210215
Unscheduled inspection
Start date: 2020-10-29, end date: 2020-11-26, duration: 20
Authority: Gosudarstvennaya inspekciya truda v Kurskoi oblasti
Purpose of inspection: Implementation of federal state supervision over compliance by a legal entity or an individual entrepreneur with the mandatory requirements of labor legislation and other normative legal acts containing labor law norms Churkin's appeal BB Prosecutor's Requirement bx 46426720TPR dated 22102020
# 461904088340
Unscheduled inspection
Start date: 2019-11-25, end date: 2019-12-02, duration: —
Authority: Glavnoe upravlenie MCHS Rossii po Kurskoi oblasti
Purpose of inspection: This inspection is carried out within the framework of the Federal State Fire Supervision registration number of the function of the Federal Republic of Germany 10001495160
# 771800101018
Unscheduled inspection
Start date: 2018-02-16, end date: 2018-03-20, duration: —
Authority: Gosudarstvennaya inspekciya truda v gorode Moskve
Purpose of inspection: Protection of the rights and interests of employees in connection with the receipt by the Inspectorate of an employee's appeal dated January 22, 2018 7191818OB on issues of remuneration, registration and termination of an employment contract